Select your motorbike

Anti-corrosion restoration kit for fibre tank from 2-5L

Reference KITPOLY

This complete Restom kit contains all you need for complete restomization of your polyester / Vinylester / carbon / ABS / Polyamide / Epoxy tank.

Degreasers - sealing resin and hardener (pre-dosed for a tank with a defined capacity)

A complete and detailed notice is delivered with, we also put you two links to explanatory and demonstrative videos.

Voir la fiche complète
Description
Compatible with
Technical sheet
Reviews 0

Restom®KitPoly  is the COMPLETE TREATMENT for the treatment of FIBER AND RESINE tanks that have already contained fuel. 

Properties

  • Suitable for polyester, carbon, vinylester, ABS, polyamide and epoxy tanks
  • This type of tanks is characteristic of Spanish, Italian and sometimes Japanese bikes (Martin, Roca hulls ...) years before 1980
    Also found in craft tanks for special vehicles (buggies, off-road, rally, light aircraft). .)
  • Suitable Diesel, SP95, SP98, 100LL Avgas, GNR, E85 Biofuels and SP95-E10
  • ⚠  Not suitable for polypropylene flexible tanks: off-road motorcycles after 1980, recent automobile tanks.
  • Protects your tank for a long time by coating a thin layer of resin on its entire inner surface
  • Stops the appearance of "blisters" of paint due to the migration of gasoline through the partition become porous.

Implementation information

Restom®Kit POLY contains:

  • Restom® SDT 4060 degreasers (no risk for polyester as it is solvent-free)
  • Restom® EIR 2000 Resin / Hardener Set

The  very detailed OPERATING INSTRUCTIONS  is enclosed in the box. Note that the distribution of products is achieved by simply rotating the tank on itself:

The treatment is simple to perform and does not require tools.
 
                         

IF TREATMENT IS ALREADY PRESENT

 

If a  treatment  is  already present  in the tank (eg original coating, or other resin or paint that peels off, etc ...),  proceed with the stripping  of it with the help of  Restom® DKPANT 4031 . Consult us for the procedure to follow.

Our advices :

  • when the capacity of the tank is "limit" compared to the proposed kits, take the kit of greater size , the structure of the polyester tending to "consume" a larger quantity of resin
  • Tanks with partitions: take a kit of larger size especially if you are close to the maximum capacity that can handle the kit
  • Light aviation tanks: consult us before purchase , some tanks already having a soft product treatment that will have to be eliminated before treatment

 

⚠ Recommendations

New polyester tanks: do not use only the resin alone (EIR 2000) but a Poly Kit WITH degreaser.

This product is universal

Reference KITPOLY
Manufacturer Restom

Subscribe to our newsletter

Don't miss any more promotions!